Opis
Sklopka D – 3P(3 NO) – AC-3 – <= 440 V 12 A - zavojnica 24 V DCl
range |
TeSys
|
---|---|
product name |
TeSys D
|
product or component type |
Contactor
|
device short name |
LC1D
|
contactor application |
Motor control
Resistive load |
utilisation category |
AC-1
AC-3 AC-4 |
poles description |
3P
|
power pole contact composition |
3 NO
|
[Ue] rated operational voltage |
<= 300 V DC for power circuit
<= 690 V AC 25...400 Hz for power circuit
|
[Ie] rated operational current |
12 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
|
motor power kW |
7.5 kW at 500 V AC 50/60 Hz AC-3
7.5 kW at 660…690 V AC 50/60 Hz AC-3 5.5 kW at 380…400 V AC 50/60 Hz AC-3 5.5 kW at 415…440 V AC 50/60 Hz AC-3 3 kW at 220…230 V AC 50/60 Hz AC-3 3.7 kW at 400 V AC 50/60 Hz AC-4 |
motor power HP (UL / CSA) |
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors |
control circuit type |
DC standard
|
[Uc] control circuit voltage |
24 V DC
|
auxiliary contact composition |
1 NO + 1 NC
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947
|
overvoltage category |
III
|
[Ith] conventional free air thermal current |
25 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
|
Irms rated making capacity |
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
rated breaking capacity |
250 A at 440 V for power circuit conforming to IEC 60947
|
[Icw] rated short-time withstand current |
105 A <= 40 °C 10 s power circuit
210 A <= 40 °C 1 s power circuit
30 A <= 40 °C 10 min power circuit
61 A <= 40 °C 1 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
|
associated fuse rating |
25 A gG at <= 690 V coordination type 2 for power circuit
40 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
|
average impedance |
2.5 mOhm at 50 Hz – Ith 25 A for power circuit
|
[Ui] rated insulation voltage |
600 V for power circuit certifications CSA
600 V for power circuit certifications UL 690 V for power circuit conforming to IEC 60947-4-1 690 V for signalling circuit conforming to IEC 60947-1 600 V for signalling circuit certifications CSA 600 V for signalling circuit certifications UL |
electrical durability |
2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
|
power dissipation per pole |
0.36 W AC-3
1.56 W AC-1 |
safety cover |
With
|
mounting support |
Plate
Rail |
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
product certifications |
BV
CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL |
connections – terminals |
Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Power circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end Power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end |
tightening torque |
Power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 |
operating time |
53.55…72.45 ms closing
16…24 ms opening |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
mechanical durability |
30 Mcycles
|
operating rate |
3600 cyc/h at <= 60 °C
|
[accordion-item title=”Original kataloÅ¡ki broj”]
LC1D12BD
[/accordion-item]
[accordion-item title=”Robna marka”]
SCHNEIDER
[/accordion-item]
[/accordion]