REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000164
LC1D18Q7 SKLPOKA 18A 3P 1NO1NC ZAVOJNICA 380V AC
OpisSpecifikacijaRecenzijeSlični proizvodi

63,50 KM

Dodaj u korpu

LC1D18Q7 SKLPOKA 18A 3P 1NO1NC ZAVOJNICA 380V AC

ŠIFRA: 50000164

63,50 KM

ŠIFRA ARTIKLA:
50000164

KATALOŠKI BROJ:
LC1D18Q7

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

Description

Sklopka

Karakteristike
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Resistive load
Motor control
utilisation category
AC-3
AC-4
AC-1
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
[Ie] rated operational current
18 A 60 °C) <= 440 V AC AC-3 power circuit 32 A 60 °C) <= 440 V AC AC-1 power circuit
motor power kW
4 kW 220…230 V AC 50/60 Hz AC-3)
7,5 kW 380…400 V AC 50/60 Hz AC-3)
9 kW 415…440 V AC 50/60 Hz AC-3)
10 kW 500 V AC 50/60 Hz AC-3)
10 kW 660…690 V AC 50/60 Hz AC-3)
4 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA)
1 hp 115 V AC 50/60 Hz 1 phase
3 hp 230/240 V AC 50/60 Hz 1 phase
5 hp 200/208 V AC 50/60 Hz 3 phases
5 hp 230/240 V AC 50/60 Hz 3 phases
10 hp 460/480 V AC 50/60 Hz 3 phases
15 hp 575/600 V AC 50/60 Hz 3 phases
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
380 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
10 A 60 °C signalling circuit
32 A 60 °C power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
300 A 440 V power circuit IEC 60947
rated breaking capacity
300 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
145 A 40 °C – 10 s power circuit
240 A 40 °C – 1 s power circuit
40 A 40 °C – 10 min power circuit
84 A 40 °C – 1 min power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
average impedance
2,5 mOhm – Ith 32 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
electrical durability
1,65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V
power dissipation per pole
2,5 W AC-1
0,8 W AC-3
safety cover
With
mounting support
Rail
Plate
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
RINA
LROS (Lloyds register of shipping)
GL
CSA
BV
GOST
DNV
CCC
UL
connections – terminals
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
Power circuit screw clamp terminals 1 1,5…6 mm²flexible without cable end
Power circuit screw clamp terminals 2 1,5…6 mm²flexible without cable end
Power circuit screw clamp terminals 1 1…6 mm²flexible with cable end
Power circuit screw clamp terminals 2 1…4 mm²flexible with cable end
Power circuit screw clamp terminals 1 1,5…6 mm²solid without cable end
Power circuit screw clamp terminals 2 1,5…6 mm²solid without cable end
tightening torque
Power circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Power circuit 1,7 N.m screw clamp terminals Philips No 2
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
operating time
12…22 ms closing
4…19 ms opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
15 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
Drop-out 0.3…0.6 Uc AC 50/60 Hz 60 °C)
Operational 0.8…1.1 Uc AC 50 Hz 60 °C)
Operational 0.85…1.1 Uc AC 60 Hz 60 °C)
inrush power in VA
70 VA 60 Hz 0,75 20 °C)
70 VA 50 Hz 0,75 20 °C)
hold-in power consumption in VA
7,5 VA 60 Hz 0,3 20 °C)
7 VA 50 Hz 0,3 20 °C)
heat dissipation
2…3 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit

[accordion-item title=”Original kataloÅ¡ki broj”]

LC1D18Q7

[/accordion-item]
[accordion-item title=”Robna marka”]

SCHNEIDER

[/accordion-item]

[/accordion]

Prijavite se na Newsletter
Prijavite se na Newsletter. Najbolje akcije i najnoviji proizvodi stižu na Vašu email adresu!