REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000282
LC1D50AP7 SKLOPKA 50A 3P 1NONC 230V
OpisSpecifikacijaRecenzijeSlični proizvodi

205,00 KM

Dodaj u korpu

LC1D50AP7 SKLOPKA 50A 3P 1NONC 230V

ŠIFRA: 50000282

205,00 KM

ŠIFRA ARTIKLA:
50000282

KATALOŠKI BROJ:
LC1D50AP7

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

Description

Sklopka-D-3P (3 NO)-AC-3-<= 440 V 50 A-zavojnica 230 V AC-50/60 Hz

Karakteristike
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-4
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
[Ie] rated operational current
50 A 60 °C) <= 440 V AC AC-3 power circuit 80 A 60 °C) <= 440 V AC AC-1 power circuit
motor power kW
15 kW 220…230 V AC 50/60 Hz AC-3)
22 kW 380…400 V AC 50/60 Hz AC-3)
30 kW 500 V AC 50/60 Hz AC-3)
33 kW 660…690 V AC 50/60 Hz AC-3)
25 kW 415 V AC 50/60 Hz AC-3)
30 kW 440 V AC 50/60 Hz AC-3)
11 kW 400 V AC 50/60 Hz AC-4)
motor power HP (UL / CSA)
3 hp 115 V AC 50/60 Hz 1 phase
7,5 hp 230/240 V AC 50/60 Hz 1 phase
15 hp 200/208 V AC 50/60 Hz 3 phases
15 hp 230/240 V AC 50/60 Hz 3 phases
40 hp 460/480 V AC 50/60 Hz 3 phases
40 hp 575/600 V AC 50/60 Hz 3 phases
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
10 A 60 °C signalling circuit
80 A 60 °C power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
900 A 440 V power circuit IEC 60947
rated breaking capacity
900 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
400 A 40 °C – 10 s power circuit
810 A 40 °C – 1 s power circuit
84 A 40 °C – 10 min power circuit
208 A 40 °C – 1 min power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
100 A gG <= 690 V type 1 power circuit 100 A gG <= 690 V type 2 power circuit
average impedance
1,5 mOhm – Ith 80 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
electrical durability
1,45 Mcycles 50 A AC-3 <= 440 V 1,1 Mcycles 80 A AC-1 <= 440 V
power dissipation per pole
3,7 W AC-3
9,6 W AC-1
safety cover
With
mounting support
Plate
Rail
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
GL
BV
GOST
CCC
CSA
UL
RINA
LROS (Lloyds register of shipping)
DNV
connections – terminals
Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
Power circuit screw connection 1 1…35 mm²flexible without cable end
Power circuit screw connection 2 1…25 mm²flexible without cable end
Power circuit screw connection 1 1…35 mm²flexible with cable end
Power circuit screw connection 2 1…25 mm²flexible with cable end
Power circuit screw connection 1 1…35 mm²solid without cable end
Power circuit screw connection 2 1…25 mm²solid without cable end
tightening torque
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
Power circuit 8 N.m EverLink BTR screw connectors 25…35 mm² hexagonal 4 mm
Power circuit 5 N.m EverLink BTR screw connectors 1…25 mm² hexagonal 4 mm
operating time
4…19 ms opening
12…26 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
6 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
Drop-out 0.3…0.6 Uc AC 50/60 Hz 60 °C)
Operational 0.8…1.1 Uc AC 50 Hz 60 °C)
Operational 0.85…1.1 Uc AC 60 Hz 60 °C)
inrush power in VA
140 VA 60 Hz 0,75 20 °C)
160 VA 50 Hz 0,75 20 °C)
hold-in power consumption in VA
13 VA 60 Hz 0,3 20 °C)
15 VA 50 Hz 0,3 20 °C)
heat dissipation
4…5 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
Environment
IP degree of protection
IP20 front face IEC 60529
protective treatment
TH IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without
fire resistance
850 °C IEC 60695-2-1
flame retardance
V1 UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5…300 Hz
Vibrations contactor closed4 Gn, 5…300 Hz
Shocks contactor closed15 Gn for 11 ms
Shocks contactor open10 Gn for 11 ms
height
122 mm
width
55 mm
depth
120 mm
net weight
0,855 kg
Prijavite se na Newsletter