REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000043
LC1D18P7 SKLOPKA <= 440 V 18A 3P 1NO+1NC Zavojnica 230V
OpisSpecifikacijaRecenzijeSlični proizvodi

59,00 KM

Dodaj u korpu

Vaša korpa je trenutno prazna.

Return to shop

LC1D18P7 SKLOPKA <= 440 V 18A 3P 1NO+1NC Zavojnica 230V

ŠIFRA: 50000043

59,00 KM

ŠIFRA ARTIKLA:
50000043

KATALOŠKI BROJ:
LC1D18P7

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

Opis

Sklopka

Karakteristike
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-4
AC-1
AC-3
poles description
3P
pole contact composition
3 NO
[Ue] rated operational voltage
<= 300 V DCfor power circuit <= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current
18 A (<= 60 °C) at <= 440 V AC AC-3for power circuit 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW
10 kW at 500 V AC 50/60 Hz AC-3
10 kW at 660…690 V AC 50/60 Hz AC-3
4 kW at 220…230 V AC 50/60 Hz AC-3
7.5 kW at 380…400 V AC 50/60 Hz AC-3
9 kW at 415…440 V AC 50/60 Hz AC-3
4 kW at 400 V AC 50/60 Hz AC-4
motor power hp
1 hp at 115 V AC 50/60 Hzfor 1 phase motors
3 hp at 230/240 V AC 50/60 Hzfor 1 phase motors
5 hp at 200/208 V AC 50/60 Hzfor 3 phases motors
5 hp at 230/240 V AC 50/60 Hzfor 3 phases motors
10 hp at 460/480 V AC 50/60 Hzfor 3 phases motors
15 hp at 575/600 V AC 50/60 Hzfor 3 phases motors
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
32 A at <= 60 °Cfor power circuit 10 A at <= 60 °Cfor signalling circuit
Irms rated making capacity
300 A at 440 V for power circuit conforming to IEC 60947
140 A ACfor signalling circuit conforming to IEC 60947-5-1
250 A DCfor signalling circuit conforming to IEC 60947-5-1
rated breaking capacity
300 A at 440 Vfor power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
145 A <= 40 °C 10 s power circuit 240 A <= 40 °C 1 s power circuit 40 A <= 40 °C 10 min power circuit 84 A <= 40 °C 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit
associated fuse rating
35 A gG at <= 690 V coordination type 2 for power circuit 50 A gG at <= 690 V coordination type 1 for power circuit 10 A gGfor signalling circuit conforming to IEC 60947-5-1
average impedance
2.5 mOhm at 50 Hz – Ith 32 Afor power circuit
[Ui] rated insulation voltage
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-1
690 Vfor signalling circuit conforming to IEC 60947-1
600 Vfor signalling circuit certifications CSA
600 Vfor signalling circuit certifications UL
electrical durability
1.65 Mcycles 18 A AC-3 at Ue <= 440 V 1 Mcycles 32 A AC-1 at Ue <= 440 V
power dissipation per pole
0.8 W AC-3
2.5 W AC-1
protective cover
With
mounting support
Rail
Plate
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
BV
DNV
GOST
GL
CSA
CCC
LROS (Lloyds register of shipping)
UL
RINA
connections – terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm² – cable stiffness: flexible – without cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² – cable stiffness: flexible – without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm² – cable stiffness: solid – without cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² – cable stiffness: solid – without cable end
tightening torque
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
operating time
4…19 ms opening
12…22 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
15 Mcycles
operating rate
3600 cyc/h at <= 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3…0.6 Uc drop-out at 60 °C, AC 50/60 Hz
0.8…1.1 Uc operational at 60 °C, AC 50 Hz
0.85…1.1 Uc operational at 60 °C, AC 60 Hz
inrush power in VA
70 VA at 20 °C (cos Ï• 0.75) 60 Hz
70 VA at 20 °C (cos Ï• 0.75) 50 Hz
hold-in power consumption in VA
7.5 VA at 20 °C (cos Ï• 0.3) 60 Hz
7 VA at 20 °C (cos Ï• 0.3) 50 Hz
heat dissipation
2…3 W at 50/60 Hz
auxiliary contacts type
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mAfor signalling circuit
minimum switching voltage
17 Vfor signalling circuit
non-overlap time
1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
insulation resistance
> 10 MOhmfor signalling circuit
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
protective treatment
TH conforming to IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without derating in temperature
fire resistance
850 °C conforming to IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz
Shocks contactor open 10 Gn for 11 ms
Shocks contactor closed 15 Gn for 11 ms
height
77 mm
width
45 mm
depth
86 mm
product weight
0.33 kg

[accordion-item title=”Original kataloÅ¡ki broj”]

LC1D18P7

[/accordion-item]
[accordion-item title=”Robna marka”]

Schneider

[/accordion-item]

[/accordion]

Prijavite se na Newsletter
Prijavite se na Newsletter. Najbolje akcije i najnoviji proizvodi stižu na Vašu email adresu!