| dielectric strength |
2040 V DC between earth and power terminals
2880 V AC between control and power terminals |
|---|---|
| electromagnetic compatibility |
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3 1.2/50 µs – 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3 |
| standards |
IEC 61800-3
IEC 61800-5-1 |
| product certifications |
CSA
C-Tick DNV GOST NOM UL |
| pollution degree |
2
|
| protective treatment |
TC
|
| vibration resistance |
1.5 mm (f = 3…13 Hz) conforming to EN/IEC 60068-2-6
1 gn (f = 13…150 Hz) conforming to EN/IEC 60068-2-6 |
| shock resistance |
15 gnfor 11 ms conforming to EN/IEC 60068-2-27
|
| relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3 |
| ambient air temperature for storage |
-25…70 °C
|
| ambient air temperature for operation |
-10…50 °C without derating with protective cover on top of the drive
-10…60 °C with derating factor without protective cover on top of the drive |
| operating altitude |
<= 1000 m without derating
1000…2000 m with current derating 1 % per 100 m |