Opis
Sklopka
range |
TeSys
|
---|---|
product name |
TeSys D
|
product or component type |
Contactor
|
device short name |
LC1D
|
contactor application |
Resistive load
Motor control |
utilisation category |
AC-1
AC-4 AC-3 |
poles description |
3P
|
power pole contact composition |
3 NO
|
[Ue] rated operational voltage |
Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
|
[Ie] rated operational current |
32 A 60 °C) <= 440 V AC AC-3 power circuit
50 A 60 °C) <= 440 V AC AC-1 power circuit
|
motor power kW |
7,5 kW 220…230 V AC 50/60 Hz AC-3)
15 kW 380…400 V AC 50/60 Hz AC-3) 15 kW 415…440 V AC 50/60 Hz AC-3) 18,5 kW 500 V AC 50/60 Hz AC-3) 18,5 kW 660…690 V AC 50/60 Hz AC-3) 7,5 kW 400 V AC 50/60 Hz AC-4) |
motor power HP (UL / CSA) |
2 hp 115 V AC 50/60 Hz 1 phase
5 hp 230/240 V AC 50/60 Hz 1 phase 7,5 hp 200/208 V AC 50/60 Hz 3 phases 10 hp 230/240 V AC 50/60 Hz 3 phases 20 hp 460/480 V AC 50/60 Hz 3 phases 30 hp 575/600 V AC 50/60 Hz 3 phases |
control circuit type |
DC standard
|
[Uc] control circuit voltage |
48 V DC
|
auxiliary contact composition |
1 NO + 1 NC
|
[Uimp] rated impulse withstand voltage |
6 kV IEC 60947
|
overvoltage category |
III
|
[Ith] conventional free air thermal current |
10 A 60 °C signalling circuit
50 A 60 °C power circuit |
Irms rated making capacity |
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947 |
rated breaking capacity |
550 A 440 V power circuit IEC 60947
|
[Icw] rated short-time withstand current |
260 A 40 °C – 10 s power circuit
430 A 40 °C – 1 s power circuit 60 A 40 °C – 10 min power circuit 138 A 40 °C – 1 min power circuit 100 A – 1 s signalling circuit 120 A – 500 ms signalling circuit 140 A – 100 ms signalling circuit |
associated fuse rating |
10 A gG signalling circuit IEC 60947-5-1
63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit |
average impedance |
2 mOhm – Ith 50 A 50 Hz power circuit
|
[Ui] rated insulation voltage |
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL |
electrical durability |
1,65 Mcycles 32 A AC-3 <= 440 V
1,4 Mcycles 50 A AC-1 <= 440 V
|
power dissipation per pole |
2 W AC-3
5 W AC-1 |
safety cover |
With
|
mounting support |
Rail
Plate |
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
product certifications |
LROS (Lloyds register of shipping)
CCC DNV RINA GOST CSA UL GL BV |
connections – terminals |
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end Control circuit screw clamp terminals 1 1…4 mm²solid without cable end Control circuit screw clamp terminals 2 1…4 mm²solid without cable end Power circuit screw clamp terminals 1 2,5…10 mm²flexible without cable end Power circuit screw clamp terminals 2 2,5…10 mm²flexible without cable end Power circuit screw clamp terminals 1 1…10 mm²flexible with cable end Power circuit screw clamp terminals 2 1,5…6 mm²flexible with cable end Power circuit screw clamp terminals 1 1,5…10 mm²solid without cable end Power circuit screw clamp terminals 2 2,5…10 mm²solid without cable end |
tightening torque |
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2 Power circuit 2,5 N.m screw clamp terminals flat Ø 6 mm Power circuit 2,5 N.m screw clamp terminals Philips No 2 |
operating time |
53.55…72.45 ms closing
16…24 ms opening |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
mechanical durability |
30 Mcycles
|
maximum operating rate |
3600 cyc/h 60 °C
|
coil technology |
Built-in bidirectional peak limiting diode suppressor
|
---|---|
control circuit voltage limits |
Drop-out 0.1…0.25 Uc DC 60 °C)
Operational 0.7…1.25 Uc DC 60 °C) |
time constant |
28 ms
|
inrush power in W |
5,4 W 20 °C)
|
hold-in power consumption in W |
5,4 W 20 °C
|
auxiliary contacts type |
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1 |
signalling circuit frequency |
25…400 Hz
|
minimum switching current |
5 mA signalling circuit
|
minimum switching voltage |
17 V signalling circuit
|
non-overlap time |
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact |
insulation resistance |
> 10 MOhm signalling circuit
|
[accordion-item title=”Original kataloÅ¡ki broj”]
LC1D32ED
[/accordion-item]
[accordion-item title=”Robna marka”]
SCHNEIDER
[/accordion-item]
[/accordion]