REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000240
LC1DT20F7 SKLOPKA 4P-440V-20A-zavojnica110V AC
OpisSpecifikacijaRecenzijeSlični proizvodi

48,00 KM

Dodaj u korpu

Vaša korpa je trenutno prazna.

Return to shop

LC1DT20F7 SKLOPKA 4P-440V-20A-zavojnica110V AC

ŠIFRA: 50000240

48,00 KM

ŠIFRA ARTIKLA:
50000240

KATALOŠKI BROJ:
LC1DT20F7

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

5 na zalihi

Uporedite

Opis

Sklopka-contakter 4P-440V-20A-zavojnica 110V AC-50/60Hz

Karakteristike
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Resistive load
utilisation category
AC-1
poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
[Ie] rated operational current
20 A 60 °C) <= 440 V AC AC-1 power circuit
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
110 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
10 A 60 °C signalling circuit
20 A 60 °C power circuit
Irms rated making capacity
140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
250 A 440 V power circuit IEC 60947
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
30 A 40 °C – 10 min power circuit
61 A 40 °C – 1 min power circuit
105 A 40 °C – 10 s power circuit
210 A 40 °C – 1 s power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1
25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit
average impedance
2,5 mOhm – Ith 20 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Power circuit 690 V IEC 60947-4-1
power dissipation per pole
1,56 W AC-1
safety cover
With
mounting support
Rail
Plate
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
BV
GOST
LROS (Lloyds register of shipping)
DNV
UL
CSA
GL
RINA
CCC
connections – terminals
Control circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Control circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Control circuit screw clamp terminals 1 1…4 mm²solid without cable end
Control circuit screw clamp terminals 2 1…4 mm²solid without cable end
Power circuit screw clamp terminals 1 1…4 mm²flexible without cable end
Power circuit screw clamp terminals 2 1…4 mm²flexible without cable end
Power circuit screw clamp terminals 1 1…4 mm²flexible with cable end
Power circuit screw clamp terminals 2 1…2,5 mm²flexible with cable end
Power circuit screw clamp terminals 1 1…4 mm²solid without cable end
Power circuit screw clamp terminals 2 1…4 mm²solid without cable end
tightening torque
Control circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Control circuit 1,7 N.m screw clamp terminals Philips No 2
Power circuit 1,7 N.m screw clamp terminals flat Ø 6 mm
Power circuit 1,7 N.m screw clamp terminals Philips No 2
operating time
4…19 ms opening
12…22 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
15 Mcycles
maximum operating rate
3600 cyc/h 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
Drop-out 0.3…0.6 Uc AC 50/60 Hz 60 °C)
Operational 0.8…1.1 Uc AC 50 Hz 60 °C)
Operational 0.85…1.1 Uc AC 60 Hz 60 °C)
inrush power in VA
70 VA 60 Hz 0,75 20 °C)
70 VA 50 Hz 0,75 20 °C)
hold-in power consumption in VA
7,5 VA 60 Hz 0,3 20 °C)
7 VA 50 Hz 0,3 20 °C)
heat dissipation
2…3 W 50/60 Hz
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mA signalling circuit
minimum switching voltage
17 V signalling circuit
non-overlap time
1,5 ms on de-energisation between NC and NO contact
1,5 ms on energisation between NC and NO contact
insulation resistance
> 10 MOhm signalling circuit
Environment
IP degree of protection
IP20 front face IEC 60529
protective treatment
TH IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without
fire resistance
850 °C IEC 60695-2-1
flame retardance
V1 UL 94
mechanical robustness
Vibrations contactor open2 Gn, 5…300 Hz
Vibrations contactor closed4 Gn, 5…300 Hz
Shocks contactor closed15 Gn for 11 ms
Shocks contactor open10 Gn for 11 ms
height
85 mm
width
45 mm
depth
92 mm
net weight
0,365 kg

[accordion-item title=”Original kataloÅ¡ki broj”]

LC1DT20F7

[/accordion-item]
[accordion-item title=”Robna marka”]

SCHNEIDER

[/accordion-item]

[/accordion]

Prijavite se na Newsletter
Prijavite se na Newsletter. Najbolje akcije i najnoviji proizvodi stižu na Vašu email adresu!