Opis
Sklopka
range of product |
TeSys K
|
---|---|
range |
TeSys
|
product or component type |
Contactor
|
product name |
TeSys K
|
device short name |
LC1K
|
device application |
Control
|
contactor application |
Motor control
|
utilisation category |
AC-3
AC-4 |
---|---|
poles description |
3P
|
pole contact composition |
3 NO
|
System Voltage |
690 V AC 50/60 Hz power circuit
<= 690 V AC 50/60 Hz signalling circuit |
[Ie] rated operational current |
6 A at <= 440 V AC AC-3 power circuit
|
control circuit type |
AC 50/60 Hz
|
[Uc] control circuit voltage |
220…230 V AC 50/60 Hz
|
motor power kW |
1.5 kW at 220…230 V AC 50/60 Hz AC-3
2.2 kW at 380…415 V AC 50/60 Hz AC-3 1.5 kW at 400 V AC 50/60 Hz AC-4 3 kW at 660…690 V AC 50/60 Hz AC-3 3 kW at 440 V AC 50/60 Hz AC-3 3 kW at 480 V AC 50/60 Hz AC-3 3 kW at 500…600 V AC 50/60 Hz AC-3 |
auxiliary contact composition |
1 NO
|
[Uimp] rated impulse withstand voltage |
8 kV
|
overvoltage category |
III
|
[Ith] conventional free air thermal current |
20 A at <= 122 °F (50 °C) power circuit
10 A at <= 122 °F (50 °C) signalling circuit
|
Irms rated making capacity |
110 A AC power circuit conforming to NF C 63-110
110 A AC power circuit conforming to IEC 60947 110 A AC signalling circuit conforming to IEC 60947 |
rated breaking capacity |
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220…230 V conforming to IEC 60947 110 A at 380…400 V conforming to IEC 60947 70 A at 660…690 V conforming to IEC 60947 |
[Icw] rated short-time withstand current |
20 A <= 50 °C >= 15 min power circuit
90 A <= 122 °F (50 °C) 1 s power circuit 85 A <= 122 °F (50 °C) 5 s power circuit 80 A <= 122 °F (50 °C) 10 s power circuit 60 A <= 122 °F (50 °C) 30 s power circuit 45 A <= 122 °F (50 °C) 1 min power circuit 40 A <= 122 °F (50 °C) 3 min power circuit 80 A 1 s signalling circuit 90 A 500 ms signalling circuit 110 A 100 ms signalling circuit |
associated fuse rating |
25 A gG at <= 440 V power circuit
25 A aM power circuit
10 A gG signalling circuit conforming to IEC 60947
10 A gG signalling circuit conforming to VDE 0660
|
average impedance |
3 mOhm at 50 Hz – Ith 20 A power circuit
|
[Ui] rated insulation voltage |
690 V signalling circuit conforming to IEC 60947-4-1
690 V signalling circuit conforming to IEC 60947-5-1 600 V signalling circuit conforming to UL 508 600 V power circuit conforming to CSA C22.2 No 14 600 V signalling circuit conforming to CSA C22.2 No 14 690 V power circuit conforming to IEC 60947-4-1 600 V power circuit conforming to UL 508 |
insulation resistance |
> 10 MOhm signalling circuit
|
inrush power in VA |
30 VA at 68 °F (20 °C)
|
hold-in power consumption in VA |
4.5 VA at 68 °F (20 °C)
|
heat dissipation |
1.3 W
|
control circuit voltage limits |
0.2…0.75 Uc at <= 122 °F (50 °C) drop-out
0.8...1.15 Uc at <= 122 °F (50 °C) operational
|
connections – terminals |
Screw clamp terminals 1 cable(s) 0…0.01 in² (1.5…4 mm²) – cable stiffness: solid
Screw clamp terminals 1 cable(s) 0…0.01 in² (0.75…4 mm²) – cable stiffness: flexible – without cable end Screw clamp terminals 1 cable(s) 0…0 in² (0.34…2.5 mm²) – cable stiffness: flexible – with cable end Screw clamp terminals 2 cable(s) 0…0.01 in² (1.5…4 mm²) – cable stiffness: solid Screw clamp terminals 2 cable(s) 0…0.01 in² (0.75…4 mm²) – cable stiffness: flexible – without cable end Screw clamp terminals 2 cable(s) 0…0 in² (0.34…1.5 mm²) – cable stiffness: flexible – with cable end |
operating rate |
3600 cyc/h
|
auxiliary contacts type |
Type instantaneous (1 NO)
|
signalling circuit frequency |
<= 400 Hz
|
minimum switching current |
5 mA signalling circuit
|
minimum switching voltage |
17 V signalling circuit
|
mounting support |
Plate
Rail |
tightening torque |
11.5 lbf.in (1.3 N.m) – on screw clamp terminals – with screwdriver Philips No 2
11.5 lbf.in (1.3 N.m) – on screw clamp terminals – with screwdriver flat Ø 6 mm |
operating time |
10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
non overlap distance |
0.02 in (0.5 mm)
|
mechanical durability |
10 Mcycles
|
electrical durability |
1.3 Mcycles 6 A AC-3 at Ue <= 440 V
|
mechanical robustness |
Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed 4 Gn, 5…300 Hz IEC 60068-2-6 Vibrations contactor opened 2 Gn, 5…300 Hz IEC 60068-2-6 |
height |
2.28 in (58 mm)
|
width |
1.77 in (45 mm)
|
depth |
2.24 in (57 mm)
|
product weight |
0.4 lb(US) (0.18 kg)
|
compatibility code |
LC1K
|
power range |
0.55…1 kW 200…240 V 3 phases
0.55…1 kW 380…440 V 3 phases 0.55…1 kW 480…500 V 3 phases 1.1…2 kW 200…240 V 3 phases 1.1…2 kW 380…440 V 3 phases 2.2…3 kW 380…440 V 3 phases 2.2…3 kW 480…500 V 3 phases 0…0.5 kW 200…240 V 3 phases 0…0.5 kW 380…440 V 3 phases 0…0.5 kW 480…500 V 3 phases 1.1…2 kW 480…500 V 3 phases |
motor starter type |
Direct on-line contactor
|
contactor coil voltage |
230 V AC standard
220 V AC standard |
[accordion-item title=”Original kataloÅ¡ki broj”]
LC1K0610M7
[/accordion-item]
[accordion-item title=”Robna marka”]
Schneider
[/accordion-item]
[/accordion]