REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000042
SR3B101FU MODULARNI RELEJ 10 I-O
OpisSpecifikacijaRecenzijeSlični proizvodi

165,00 KM

Dodaj u korpu

Vaša korpa je trenutno prazna.

Return to shop

SR3B101FU MODULARNI RELEJ 10 I-O

ŠIFRA: 50000042

165,00 KM

ŠIFRA ARTIKLA:
50000042

KATALOŠKI BROJ:
SR3B101FU

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

Opis

Modularni relej

Karakteristike
range of product
Zelio Logic
product or component type
Modular smart relay
Complementary
local display
With
number or control scheme lines
0…500 with FBD programming
0…240 with ladder programming
cycle time
6…90 ms
backup time
10 years at 25 °C
clock drift
6 s/month at 25 °C
12 min/year at 0…55 °C
checks
Program memory on each power up
[Us] rated supply voltage
100…240 V
supply voltage limits
85…264 V
supply frequency
50/60 Hz
supply current
30 mA at 240 V (without extension)
40 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)
80 mA at 100 V (without extension)
power consumption in VA
12 VA with extensions
7 VA without extension
isolation voltage
1780 V
protection type
Against inversion of terminals (control instructions not executed)
discrete input number
6
discrete input voltage
100…240 V AC
discrete input current
0.6 mA
discrete input frequency
47…53 Hz
57…63 Hz
voltage state 1 guaranteed
>= 79 Vfor discrete input
voltage state 0 guaranteed
<= 40 Vfor discrete input
current state 1 guaranteed
>= 0.17 mAfor discrete input
current state 0 guaranteed
<= 0.5 mAfor discrete input
input impedance
350 kOhm (discrete input)
number of outputs
4 relay output(s)
output voltage limits
24…250 V AC
5…30 V DC (relay output)
contacts type and composition
NOfor relay output
output thermal current
8 A for all 4 outputs (relay output)
electrical durability
500000 cycles AC-12 at 230 V, 1.5 Afor relay output conforming to EN/IEC 60947-5-1
500000 cycles AC-15 at 230 V, 0.9 Afor relay output conforming to EN/IEC 60947-5-1
500000 cycles DC-12 at 24 V, 1.5 Afor relay output conforming to EN/IEC 60947-5-1
500000 cycles DC-13 at 24 V, 0.6 Afor relay output conforming to EN/IEC 60947-5-1
switching capacity in mA
>= 10 mA at 12 V (relay output)
operating rate in Hz
0.1 Hz (at Ie)for relay output
10 Hz (no load)for relay output
mechanical durability
10000000 cycles (relay output)
[Uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
clock
With
response time
10 ms (from state 0 to state 1)for relay output
5 ms (from state 1 to state 0)for relay output
50 ms with ladder programming (from state 0 to state 1)for discrete input
50 ms with ladder programming (from state 1 to state 0)for discrete input
50…255 ms with FBD programming (from state 0 to state 1)for discrete input
50…255 ms with FBD programming (from state 1 to state 0)for discrete input
connections – terminals
Screw terminals, clamping capacity: 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14 semi-solid
Screw terminals, clamping capacity: 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14 solid
Screw terminals, clamping capacity: 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14 flexible with cable end
Screw terminals, clamping capacity: 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16 solid
Screw terminals, clamping capacity: 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18 flexible with cable end
tightening torque
0.5 N.m
overvoltage category
III conforming to EN/IEC 60664-1
product weight
0.25 kg
Environment
immunity to microbreaks
<= 10 ms
product certifications
CSA
C-Tick
GL
GOST
UL
standards
EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-11
EN/IEC 61000-4-12
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
IP degree of protection
IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
environmental characteristic
EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2
disturbance radiated/conducted
Class B conforming to EN 55022-11 group 1
pollution degree
2 conforming to EN/IEC 61131-2
ambient air temperature for operation
-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
ambient air temperature for storage
-40…70 °C
operating altitude
2000 m
altitude transport
<= 3048 m
relative humidity
95 % without condensation or dripping water