Description
Frekventni pretvaraC
| range of product |
Altivar 12
|
|---|---|
| product or component type |
Variable speed drive
|
| product destination |
Asynchronous motors
|
| product specific application |
Simple machine
|
| assembly style |
With heat sink
|
| component name |
ATV12
|
| quantity per set |
Set of 1
|
| EMC filter |
Integrated
|
| built-in fan |
Without
|
| network number of phases |
1 phase
|
| [Us] rated supply voltage |
200…240 V – 15…10 %
|
| motor power kW |
0.37 kW
|
| motor power hp |
0.55 hp
|
| communication port protocol |
Modbus
|
| line current |
5.9 A 200 V
4.9 A 240 V |
| speed range |
1…20
|
| transient overtorque |
150…170 % of nominal motor torque depending on drive rating and type of motor
|
| asynchronous motor control profile |
Quadratic voltage/frequency ratio
Sensorless flux vector control Voltage/frequency ratio (V/f) |
| IP degree of protection |
IP20 without blanking plate on upper part
|
| noise level |
0 dB
|
| supply frequency |
50/60 Hz +/- 5 %
|
|---|---|
| connector type |
1 RJ45 Modbus on front face
|
| physical interface |
2-wire RS 485 Modbus
|
| transmission frame |
RTU Modbus
|
| transmission rate |
4800 bit/s
9600 bit/s 19200 bit/s 38400 bit/s |
| number of addresses |
1…247 Modbus
|
| communication service |
Read holding registers (03) 29 words
Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
| prospective line Isc |
<= 1 kA
|
| continuous output current |
2.4 A 4 kHz
|
| maximum transient current |
3.6 A 60 s
|
| speed drive output frequency |
0.5…400 Hz
|
| nominal switching frequency |
4 kHz
|
| switching frequency |
2…16 kHz adjustable
4…16 kHz with derating factor |
| braking torque |
Up to 70 % of nominal motor torque without braking resistor
|
| motor slip compensation |
Adjustable
Preset in factory |
| output voltage |
200…240 V 3 phases
|
| electrical connection |
Terminal 3.5 mm² AWG 12 L1, L2, L3, U, V, W, PA, PC
|
| tightening torque |
0.8 N.m
|
| insulation |
Electrical between power and control
|
| supply |
Internal supply for reference potentiometer 5 V DC 4.75…5.25 V 10 mA overload and short-circuit protection
Internal supply for logic inputs 24 V DC 20.4…28.8 V 100 mA overload and short-circuit protection |
| analogue input number |
1
|
| analogue input type |
Configurable voltage AI1 0…10 V 30 kOhm
Configurable voltage AI1 0…5 V 30 kOhm Configurable current AI1 0…20 mA 250 Ohm |
| discrete input number |
4
|
| discrete input type |
Programmable LI1…LI4 24 V 18…30 V
|
| discrete input logic |
Negative logic (sink) > 16 V < 10 V 3.5 kOhm
Positive logic (source) 0…< 5 V > 11 V |
| sampling duration |
20 ms +/- 1 ms logic input
10 ms analogue input |
| linearity error |
+/- 0.3 % of maximum value analogue input
|
| analogue output number |
1
|
| analogue output type |
Software-configurable voltage AO1 0…10 V 470 Ohm 8 bits
Software-configurable current AO1 0…20 mA 800 Ohm 8 bits |
| discrete output number |
2
|
| discrete output type |
Logic output LO+, LO-
Protected relay output R1A, R1B, R1C 1 C/O |
| minimum switching current |
5 mA 24 V DC logic relay
|
| maximum switching current |
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms logic relay
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms logic relay 3 A 250 V AC resistive cos phi = 1 L/R = 0 ms logic relay 4 A 30 V DC resistive cos phi = 1 L/R = 0 ms logic relay |
| acceleration and deceleration ramps |
Linear from 0 to 999.9 s
S U |
| braking to standstill |
By DC injection <= 30 s
|
| protection type |
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases |
| frequency resolution |
0.1 Hz display unit
Converter A/D, 10 bits analog input |
| time constant |
20 ms +/- 1 ms for reference change
|
| marking |
CE
|
| operating position |
Vertical +/- 10 degree
|
| height |
143 mm
|
| width |
72 mm
|
| depth |
121.2 mm
|
| product weight |
0.7 kg
|
| functionality |
Basic
|
| specific application |
Commercial equipment
|
| discrete and process manufacturing |
Commercial equipment : mixer
Commercial equipment : other application Textile : ironing |
| motor starter type |
Variable speed drive
|
| electromagnetic compatibility |
Immunity to conducted disturbances level 3 EN/IEC 61000-4-6
Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 |
|---|---|
| electromagnetic emission |
Radiated emissions environment 1 category C2 EN/IEC 61800-3 2…16 kHz shielded motor cable
Conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable 5 m Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2…12 kHz shielded motor cable 5 m Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable 10 m Conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4…12 kHz shielded motor cable 20 m Conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4…12 kHz shielded motor cable 50 m Conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4…12 kHz shielded motor cable 50 m |
| product certifications |
CSA
C-Tick GOST NOM UL |
| vibration resistance |
1 gn EN/IEC 60068-2-6 13…200 Hz
1.5 mm peak to peak EN/IEC 60068-2-6 3…13 Hz drive unmounted on symmetrical DIN rail |
| shock resistance |
15 gn EN/IEC 60068-2-27 11 ms
|
| relative humidity |
5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3 |
| ambient air temperature for storage |
-25…70 °C
|
| ambient air temperature for operation |
-10…40 °C protective cover from the top of the drive removed
40…60 °C with current derating 2.2 % per °C |
| operating altitude |
> 1000…2000 m with current derating 1 % per 100 m
<= 1000 m without derating |
[accordion-item title=”Original kataloÅ¡ki broj”]
ATV12H037M2
[/accordion-item]
[accordion-item title=”Robna marka”]
Schneider
[/accordion-item]
[/accordion]