REGISTRUJTE SE NA NAŠ B2B SHOP
POSEBNA PONUDA ZA SERVISERE I MAJSTORE
Dobrodošli na naš ONLINE SHOP
Dobrodošli na naš ONLINE SHOP
50000045
LC1D25P7 SKLOPKA <= 440 V 25 A 3P 1NO+1NC Zavojnica 230 V
OpisSpecifikacijaRecenzijeSlični proizvodi

88,50 KM

Dodaj u korpu

Vaša korpa je trenutno prazna.

Return to shop

LC1D25P7 SKLOPKA <= 440 V 25 A 3P 1NO+1NC Zavojnica 230 V

ŠIFRA: 50000045

88,50 KM

ŠIFRA ARTIKLA:
50000045

KATALOŠKI BROJ:
LC1D25P7

ZAMJENSKI PROIZVODI:

0000

NAŠ  PARTNER:
Schneider

 

Opis

Sklopka

Karakteristike
range
TeSys
product name
TeSys D
product or component type
Contactor
device short name
LC1D
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-3
AC-4
poles description
3P
pole contact composition
3 NO
[Ue] rated operational voltage
<= 300 V DCfor power circuit <= 690 V AC 25...400 Hz for power circuit
[Ie] rated operational current
25 A (<= 60 °C) at <= 440 V AC AC-3for power circuit 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW
11 kW at 380…400 V AC 50/60 Hz AC-3
15 kW at 500 V AC 50/60 Hz AC-3
15 kW at 660…690 V AC 50/60 Hz AC-3
5.5 kW at 220…230 V AC 50/60 Hz AC-3
11 kW at 415…440 V AC 50/60 Hz AC-3
5.5 kW at 400 V AC 50/60 Hz AC-4
motor power hp
2 hp at 115 V AC 50/60 Hzfor 1 phase motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 230/240 V AC 50/60 Hzfor 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hzfor 3 phases motors
15 hp at 460/480 V AC 50/60 Hzfor 3 phases motors
20 hp at 575/600 V AC 50/60 Hzfor 3 phases motors
control circuit type
AC 50/60 Hz
[Uc] control circuit voltage
230 V AC 50/60 Hz
auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
overvoltage category
III
[Ith] conventional free air thermal current
40 A at <= 60 °Cfor power circuit 10 A at <= 60 °Cfor signalling circuit
Irms rated making capacity
450 A at 440 V for power circuit conforming to IEC 60947
140 A ACfor signalling circuit conforming to IEC 60947-5-1
250 A DCfor signalling circuit conforming to IEC 60947-5-1
rated breaking capacity
450 A at 440 Vfor power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
120 A <= 40 °C 1 min power circuit 240 A <= 40 °C 10 s power circuit 380 A <= 40 °C 1 s power circuit 50 A <= 40 °C 10 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit
associated fuse rating
40 A gG at <= 690 V coordination type 2 for power circuit 63 A gG at <= 690 V coordination type 1for power circuit 10 A gGfor signalling circuit conforming to IEC 60947-5-1
average impedance
2 mOhm at 50 Hz – Ith 40 Afor power circuit
[Ui] rated insulation voltage
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-1
690 Vfor signalling circuit conforming to IEC 60947-1
600 Vfor signalling circuit certifications CSA
600 Vfor signalling circuit certifications UL
electrical durability
1.65 Mcycles 25 A AC-3 at Ue <= 440 V 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
power dissipation per pole
3.2 W AC-1
1.25 W AC-3
protective cover
With
mounting support
Plate
Rail
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
product certifications
BV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UL
connections – terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² – cable stiffness: solid – without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm² – cable stiffness: solid – without cable end
tightening torque
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2
operating time
4…19 ms opening
12…22 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
15 Mcycles
operating rate
3600 cyc/h at <= 60 °C
Complementary
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3…0.6 Uc drop-out at 60 °C, AC 50/60 Hz
0.8…1.1 Uc operational at 60 °C, AC 50 Hz
0.85…1.1 Uc operational at 60 °C, AC 60 Hz
inrush power in VA
70 VA at 20 °C (cos Ï• 0.75) 60 Hz
70 VA at 20 °C (cos Ï• 0.75) 50 Hz
hold-in power consumption in VA
7.5 VA at 20 °C (cos Ï• 0.3) 60 Hz
7 VA at 20 °C (cos Ï• 0.3) 50 Hz
heat dissipation
2…3 W at 50/60 Hz
auxiliary contacts type
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1
signalling circuit frequency
25…400 Hz
minimum switching current
5 mAfor signalling circuit
minimum switching voltage
17 Vfor signalling circuit
non-overlap time
1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
insulation resistance
> 10 MOhmfor signalling circuit
Environment
IP degree of protection
IP20 front face conforming to IEC 60529
protective treatment
TH conforming to IEC 60068-2-30
pollution degree
3
ambient air temperature for operation
-5…60 °C
ambient air temperature for storage
-60…80 °C
permissible ambient air temperature around the device
-40…70 °C at Uc
operating altitude
3000 m without derating in temperature
fire resistance
850 °C conforming to IEC 60695-2-1
flame retardance
V1 conforming to UL 94
mechanical robustness
Vibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz
Shocks contactor closed 15 Gn for 11 ms
Shocks contactor open 8 Gn for 11 ms
height
85 mm
width
45 mm
depth
92 mm
product weight
0.37 kg

[accordion-item title=”Original kataloÅ¡ki broj”]

LC1D25P7

[/accordion-item]
[accordion-item title=”Robna marka”]

Schneider

[/accordion-item]

[/accordion]

Prijavite se na Newsletter
Prijavite se na Newsletter. Najbolje akcije i najnoviji proizvodi stižu na Vašu email adresu!