Description
Sklopka
range |
TeSys
|
---|---|
product name |
TeSys D
|
product or component type |
Contactor
|
device short name |
LC1D
|
contactor application |
Resistive load
Motor control |
utilisation category |
AC-1
AC-3 AC-4 |
poles description |
3P
|
power pole contact composition |
3 NO
|
[Ue] rated operational voltage |
<= 300 V DCfor power circuit
<= 690 V AC 25...400 Hz for power circuit
|
[Ie] rated operational current |
32 A (<= 60 °C) at <= 440 V AC AC-3for power circuit
50 A (<= 60 °C) at <= 440 V AC AC-1for power circuit
|
motor power kW |
15 kW at 380…400 V AC 50/60 Hz AC-3
7.5 kW at 220…230 V AC 50/60 Hz AC-3 18.5 kW at 500 V AC 50/60 Hz AC-3 18.5 kW at 660…690 V AC 50/60 Hz AC-3 15 kW at 415…440 V AC 50/60 Hz AC-3 7.5 kW at 400 V AC 50/60 Hz AC-4 |
motor power HP (UL / CSA) |
2 hp at 115 V AC 50/60 Hzfor 1 phase motors
5 hp at 230/240 V AC 50/60 Hzfor 1 phase motors 7.5 hp at 200/208 V AC 50/60 Hzfor 3 phases motors 10 hp at 230/240 V AC 50/60 Hzfor 3 phases motors 20 hp at 460/480 V AC 50/60 Hzfor 3 phases motors 30 hp at 575/600 V AC 50/60 Hzfor 3 phases motors |
control circuit type |
AC 50/60 Hz
|
[Uc] control circuit voltage |
110 V AC 50/60 Hz
|
auxiliary contact composition |
1 NO + 1 NC
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947
|
overvoltage category |
III
|
[Ith] conventional free air thermal current |
50 A at <= 60 °Cfor power circuit
10 A at <= 60 °Cfor signalling circuit
|
Irms rated making capacity |
550 A at 440 Vfor power circuit conforming to IEC 60947
140 A ACfor signalling circuit conforming to IEC 60947-5-1 250 A DCfor signalling circuit conforming to IEC 60947-5-1 |
rated breaking capacity |
550 A at 440 Vfor power circuit conforming to IEC 60947
|
[Icw] rated short-time withstand current |
138 A <= 40 °C 1 min power circuit
260 A <= 40 °C 10 s power circuit
430 A <= 40 °C 1 s power circuit
60 A <= 40 °C 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
|
associated fuse rating |
63 A gG at <= 690 V coordination type 1for power circuit
63 A gG at <= 690 V coordination type 2for power circuit
10 A gGfor signalling circuit conforming to IEC 60947-5-1
|
average impedance |
2 mOhm at 50 Hz – Ith 50 Afor power circuit
|
[Ui] rated insulation voltage |
600 V for power circuit certifications CSA
600 V for power circuit certifications UL 690 V for power circuit conforming to IEC 60947-4-1 690 Vfor signalling circuit conforming to IEC 60947-1 600 Vfor signalling circuit certifications CSA 600 Vfor signalling circuit certifications UL |
electrical durability |
1.65 Mcycles 32 A AC-3 at Ue <= 440 V
1.4 Mcycles 50 A AC-1 at Ue <= 440 V
|
power dissipation per pole |
2 W AC-3
5 W AC-1 |
safety cover |
With
|
mounting support |
Rail
Plate |
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
product certifications |
UL
DNV CCC GL GOST LROS (Lloyds register of shipping) RINA CSA BV |
connections – terminals |
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² – cable stiffness: solid – without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm² – cable stiffness: flexible – without cable end Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² – cable stiffness: flexible – with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² – cable stiffness: flexible – with cable end Power circuit: screw clamp terminals 2 cable(s) 2.5…10 mm² – cable stiffness: solid – without cable end |
tightening torque |
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver Philips No 2 |
operating time |
4…19 ms opening
12…22 ms closing |
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
mechanical durability |
15 Mcycles
|
operating rate |
3600 cyc/h at <= 60 °C
|
coil technology |
Without built-in suppressor module
|
---|---|
control circuit voltage limits |
0.3…0.6 Uc drop-out at 60 °C, AC 50/60 Hz
0.8…1.1 Uc operational at 60 °C, AC 50 Hz 0.85…1.1 Uc operational at 60 °C, AC 60 Hz |
inrush power in VA |
70 VA at 20 °C (cos Ï• 0.75) 60 Hz
70 VA at 20 °C (cos Ï• 0.75) 50 Hz |
hold-in power consumption in VA |
7.5 VA at 20 °C (cos Ï• 0.3) 60 Hz
7 VA at 20 °C (cos Ï• 0.3) 50 Hz |
heat dissipation |
2…3 W at 50/60 Hz
|
auxiliary contacts type |
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
signalling circuit frequency |
25…400 Hz
|
minimum switching current |
5 mAfor signalling circuit
|
minimum switching voltage |
17 Vfor signalling circuit
|
non-overlap time |
1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact |
insulation resistance |
> 10 MOhmfor signalling circuit
|
[accordion-item title=”Original kataloÅ¡ki broj”]
LC1D32F7
[/accordion-item]
[accordion-item title=”Robna marka”]
SCHNEIDER
[/accordion-item]
[/accordion]