Opis
control station type |
Double insulated
|
---|---|
enclosure material |
Glass reinforced polyester
|
electrical circuit type |
Power circuit
|
enclosure type |
Complete ready for use
|
control station application |
Control of 2-speed hoist motor
|
control station composition |
2 push-buttons + 1 emergency stop
|
control button type |
Stop push-button Ø 40 mm 3 NC latching
First push-button 2-pole raise, slow-fast Second push-button 2-pole lower, slow-fast |
product compatibility |
XESD1291 for reversing operation
XACS499 for emergency stop |
mechanical interlocking |
With mechanical interlocking
|
control station colour |
Yellow
|
connections – terminals |
Screw clamp terminals 1 x 2.5 mm² with or without cable end
Screw clamp terminals 2 x 1.5 mm² with or without cable end |
standards |
EN/IEC 60204-32
EN/IEC 60947-5-1 CSA C22.2 No 14 |
product certifications |
CSA type 4
|
protective treatment |
TH
|
ambient air temperature for operation |
-25…70 °C
|
ambient air temperature for storage |
-40…70 °C
|
vibration resistance |
15 gn 10…500 Hz IEC 60068-2-6
|
shock resistance |
100 gn IEC 60068-2-27
|
overvoltage category |
Class II IEC 61140
|
IP degree of protection |
IP65 IEC 60529
|
mechanical durability |
1000000 cycles
|
cable entry |
Rubber sleeve with stepped entry 10…22 mm
|
[Ithe] conventional enclosed thermal current |
12 A
|
[Ui] rated insulation voltage |
400 V 3 IEC 60947-1 emergency stop contact
600 V CSA |
[Uimp] rated impulse withstand voltage |
6 kV IEC 60947-1
|
contact operation |
Snap action
|
operating force |
17 N push-button
40 N emergency stop |
short-circuit protection |
<= 10 A fuse protection cartridge aM
|
rated power in hp |
2 hp CSA 240 V
3 hp CSA 600 V 5 hp CSA 400 V |
rated operational power in W |
2200 W AC-3 240 V IEC 60947-3 appendix A
2200 W AC-3 400 V IEC 60947-3 appendix A 2200 W AC-4 240 V IEC 60947-3 appendix A 2200 W AC-4 400 V IEC 60947-3 appendix A |
electrical durability |
300000 cycles AC-3 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
300000 cycles AC-3 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 300000 cycles AC-4 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 300000 cycles AC-4 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 500000 cycles AC-3 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 500000 cycles AC-4 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 800000 cycles AC-3 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 800000 cycles AC-4 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A |
terminals description ISO n°1 |
(13-14)NO
(23-24)NO (33-34)NO (43-44)NO (51-52-54)OC (61-62-64)OC |
terminals description ISO n°2 |
(11-12)NC
(21-22)NC (31-32)NC |
terminal identifier |
(11-12)NC
(13-14)NO |
product weight |
0.99 kg
|
control station type |
Double insulated
|
---|---|
enclosure material |
Glass reinforced polyester
|
electrical circuit type |
Power circuit
|
enclosure type |
Complete ready for use
|
control station application |
Control of 2-speed hoist motor
|
control station composition |
2 push-buttons + 1 emergency stop
|
control button type |
Stop push-button Ø 40 mm 3 NC latching
First push-button 2-pole raise, slow-fast Second push-button 2-pole lower, slow-fast |
product compatibility |
XESD1291 for reversing operation
XACS499 for emergency stop |
mechanical interlocking |
With mechanical interlocking
|
control station colour |
Yellow
|
connections – terminals |
Screw clamp terminals 1 x 2.5 mm² with or without cable end
Screw clamp terminals 2 x 1.5 mm² with or without cable end |
standards |
EN/IEC 60204-32
EN/IEC 60947-5-1 CSA C22.2 No 14 |
product certifications |
CSA type 4
|
protective treatment |
TH
|
ambient air temperature for operation |
-25…70 °C
|
ambient air temperature for storage |
-40…70 °C
|
vibration resistance |
15 gn 10…500 Hz IEC 60068-2-6
|
shock resistance |
100 gn IEC 60068-2-27
|
overvoltage category |
Class II IEC 61140
|
IP degree of protection |
IP65 IEC 60529
|
mechanical durability |
1000000 cycles
|
cable entry |
Rubber sleeve with stepped entry 10…22 mm
|
[Ithe] conventional enclosed thermal current |
12 A
|
[Ui] rated insulation voltage |
400 V 3 IEC 60947-1 emergency stop contact
600 V CSA |
[Uimp] rated impulse withstand voltage |
6 kV IEC 60947-1
|
contact operation |
Snap action
|
operating force |
17 N push-button
40 N emergency stop |
short-circuit protection |
<= 10 A fuse protection cartridge aM
|
rated power in hp |
2 hp CSA 240 V
3 hp CSA 600 V 5 hp CSA 400 V |
rated operational power in W |
2200 W AC-3 240 V IEC 60947-3 appendix A
2200 W AC-3 400 V IEC 60947-3 appendix A 2200 W AC-4 240 V IEC 60947-3 appendix A 2200 W AC-4 400 V IEC 60947-3 appendix A |
electrical durability |
300000 cycles AC-3 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A
300000 cycles AC-3 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 300000 cycles AC-4 2200 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 300000 cycles AC-4 2200 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 500000 cycles AC-3 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 500000 cycles AC-4 1500 W 240 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 800000 cycles AC-3 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A 800000 cycles AC-4 1500 W 400 V 10 cyc/mn 0.4 IEC 60947-3 appendix A |
terminals description ISO n°1 |
(13-14)NO
(23-24)NO (33-34)NO (43-44)NO (51-52-54)OC (61-62-64)OC |
terminals description ISO n°2 |
(11-12)NC
(21-22)NC (31-32)NC |
terminal identifier |
(11-12)NC
(13-14)NO |
product weight |
0.99 kg
|